Velocity 3.1 R3, released 03/18/2011

This DVD contains Velocity 3.1 R3 for NEW installations (Part number: VEL).  If Velocity 3.0 is already installed, this DVD will upgrade it to Velocity 3.1 R3.  If Velocity 2.6 SP2 is already installed, you MUST first upgrade to Velocity 3.1 R2 prior to applying the Update for Velocity 3.1 (KB600) which contains all files necessary to bring you to latest 3.1 R3 version.  If you are If you are currently running a Velocity system older than 2.6 SP2 you must contact your local Hirsch Dealer or Hirsch Sales representative to purchase the appropriate update CD’s.

To order a CD Set for an existing Velocity customer running an older version (1.0.9.60, 2.5.0.28, 2.5.0.35, 2.5.0.37, 2.6.0.15) who wants to update to Velocity 2.6 Service Pack 2 you will need to use part number (s) VEL-UPD25 and VEL-UPD26 and VEL-UPD26sp1 and VEL-UPDsp2.  Please contact your dealer or Hirsch Electronics representative for the part numbers for your specific needs.  Alternately, customers may order part number VEL-UPDSUITE if they are running any version 2.0 or older.   It contains all upgrades from 2.0 to 3.1 R3.

Installation Prerequisites:

Product Packaging for Hirsch Electronics part number VEL

Velocity 3.1 R3 Supported Operating System and Database Configurations

The following are the supported Operating System and Database Configurations for Velocity 3.1 R3 Server, Single-User Workstations and Clients:

Velocity Mode  

Operating System 

Database

Server (Option 1) Windows Server 2008 R2 Standard Edition (64-Bit) SQL Server 2008 Standard or Enterprise Edition with SP1 (full version or SQL Server 2008 R2 Express (included on disk)
Server (Option 2) Windows Server 2003 Standard or Enterprise Edition with SP2 (32-Bit or 64-Bit) SQL Server 2005 Standard or Enterprise Edition with SP3 (32-Bit or 64-Bit); SQL Server 2008 Sandard or Enterprise Edition with SP1 or SQL Server 2008 R2 Express (included on disk)
Single-User Workstation Windows XP Pro with SP3 (32-Bit or 64-Bit), Windows Vista (32-Bit or 64-Bit) or
Windows 7 (32-Bit or 64-Bit)
SQL Server 2008 R2 Express (included on disk)
Client
(Communicates with a host Velocity Server)
Windows XP Pro with SP3 (32-Bit or 64-Bit), Windows Vista (32-Bit or 64-Bit) or Windows 7 (32-Bit or 64-Bit) Not applicable; connects to Velocity Server for its database

NOTE:

Velocity 3.1 R3 is not backwardly compatible and does NOT work with SQL Server 7, SQL 2000 and MSDE.
  • If SQL Server 2008 or Express is pre-installed, you may choose to create a named instance for Velocity to use and select it during the install process or you may elect to use the default instance if you do not want a named instance.

  • Installations of SQL Server 2008 R2 Express Edition performed by the Velocity installer will enable server side "Forced Encryption" for protection between the server and clients.  It will only do this with a HIRSCH named instance of SQL Server 2008 R2 Express Edition.

Velocity 3.1 R3 CCM Firmware Requirements

The Velocity 3.1 R3 release requires that you be running DIGI*TRAC CCM Firmware 7.4.31 or higher.  At the time this version was packaged the current shipping CCM version is 7.4.43.  Failure to perform this update will result in unpredictable product behavior.  The most recent firmware can be found in the \Velocity\Firmware\DIGI-TRAC directory on this Velocity 3.1 R3 DVD.

IMPORTANT CCM 7.3.0 or HIGHER FLASH UPDATE INFORMATION

Before you can flash your current 7.2.x version CCM to 7.3.0 or higher you must first check the BIOS level of the CCM.  In order for the 7.3.0 flash update to work properly you must be running a CCM with a BIOS level of 7.1.20 or higher.  If you are running a BIOS Level less than 7.1.20 you will need to replace your CCM (DO NOT ATTEMPT TO FLASH IT THROUGH VELOCITY). The current shipping CCM BIOS Level at the time of this release is 7.3.17. To determine the BIOS level of a CCM you will need to use the Velocity Diagnostic Window found under the Help Menu.

How to determine your CCM BIOS Level

1. Go to the Help menu on the tool bar and click on the Diagnostic Window option. 

2. From within the Diagnostic Window use the Controller list box and select the appropriate controller.  Now go over to the Diagnostic Command list box and select option 1 - Date, Time, Version Number and click the button next to this list box.  The controller will display system information in the bottom pane of this window.  Please look for the following information below and determine the BIOS level of your CCM.  In this example we were running CCM BIOS 7.2.19.  The Firmware version number may be very different than the BIOS number.  Please remember to only determine the BIOS Level.

1:24:40 PM 001:001:001 SNET Message 139 Device Info Device Type 3 M2
1:24:40 PM . ROM Sig. ffffffffffffffffx BIOS=7.2.19 Firmware Date=20041027 Vn. 7.3.01

3. If you are running BIOS Level 7.1.20 or higher you can use Velocity to flash your CCM to 7.3.0 or higher.

Velocity 3.1 R3 SNIB2 Firmware Requirements

1. Velocity 3.1 R3 requires that you be running SNIB2 Firmware 5.98 or higher.  At the time this version was packaged the current shipping SNIB2 Firmware version is 5.98.

IMPORTANT SNIB2 INFORMATION

If you plan on deploying the SNIB2 high-security communication board you must update your controllers with DIGI*TRAC Firmware 7.3.0 or higher prior to installation of this board in your controller.  Please refer to the DIGI*TRAC section in the Velocity Browser's Velocity Learning Center and review the DIGI*TRAC Design and Installation Guide prior to updating your controllers with the SNIB2.

Velocity 3.1 R3 XBox Firmware Requirements

1. Velocity 3.1 R3 requires that you be running XBOX Firmware 2.45/3.15.  At the time this version was packaged the currently shipping XBox Firmware version is 3.15.

Installation Notes

Upgrading Velocity 3.0 System to Velocity 3.1 R3

Important Notes:  Before updating Velocity, you must be logged into the Server with an "account" that has Administrator rights.  If you attempt to install without such rights, the Installer will not continue.

 

You must upgrade the Server machine first.  You will upgrade the client machine after the server completes its upgrade.  Both server and client machines must be upgraded in order to use this version. 

 

The Server upgrade could take several minutes or more depending on the size of your database.  Please do this upgrade off hours, and understand Velocity clients will not be able to connect to the Server during the upgrade process.

 

For more detail Information regarding the Upgrade, refer to the Velocity Quick Install Guide.

NOTE:

Velocity 3.1 R3 is NOT backwardly compatible and does NOT work with older SQL Server editions:  neither SQL Server 7.0, MSDE  nor SQL 2000 Server.

Upgrading Velocity 2.6 SP2 System to Velocity 3.1 R3

Upgrading from Velocity 2.6 SP2 to Velocity 3.1 R3 must follow a "Two-Step Installation" process. This is necessary since the SQL Server 7, SQL 2000 Server, or MSDE installed with 2.6 are not compatible with the SQL Server 2008 version installed with Velocity 3.1 R3.   For installation notes, refere to the Velocity 3.1 Installation Guide or 3.1 Quick Install Guide.

If you plan to use Windows Server 2008 R2 and SQL Server 2008 with Velocity 3.1 R3, we recommend that you migrate to a new machine using the database on your existing machine as the backup for the SQL database.

What's New in Velocity 3.1 R3

Installation

  • Support for Microsoft SQL Server 2008 R2 Express Edition

  • Support for Windows 7 (Single-User Workstation installation)

What's Fixed in Velocity 3.1 (KB600)

PRB - An application error occurred when restricting access via Roles to only view an M64 Controller

Symptom:  When selecting the Relay folder to only view an M64 Controller with restricted access via Roles, the following error occurred:

Description: Item cannot be found in the collection corresponding to the requested name or ordinal.
Function: ADODB.Fields.FAdministration.Hardware_NodeClick(84)
Error Number: 3265

Cause:  This function failed due to an SQL error.

Solution:  To resolve this problem, apply
Update for Velocity 3.1 (KB600)

Applies To:  VEL-473

PRB:  The Disable "Right Click" function via Roles in Graphics do not work

Symptom:  While in Graphics, it does not allow you to disable the "Right Click" option even it is disabled via Roles.

Solution:  To resolve this issue, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-564

PRB:  Inconsistent date format appears in the print preview when defined in the User Defined Field (UDF)

Symptom:  When a UDF is set to be a specific Date format such as MM/DD/YYYY and you attempt to preview the badge template, you will notice that the badge will display or print as YYYY/MM/DD.

Cause:  Due to a minor programming error, the UDF date field in the Enrollment Manager is not recognizing the localized date format consistently.

Solution:  Badge Printing was modified to display the UDF date field in the localized date format. To resolve this problem, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-579

PRB:  Changing a Linked Credential Template does not download the associated credentials

Symptom:  When changing a Linked Credential Template, the associated credential will not download and instead will send a message “Operator started download of all controller setups:" in the Event Viewer

Cause:  Due to an internal software defect, the Linked Credential Template is not downloading the associated credential.
Workaround:  Right click mouse the Controller and select Download Credential.

Solution: 
To resolve this problem, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-584, VEL-692

PRB:  Adding or modifying a credential template is generating a download of all controller setups

Symptom:  When adding or modifying the Credential Template, the associated credential will not download and instead will perform a “download of all controller setups".

Cause: 
Due to an internal software defect, the Credential Template is not downloading the associated credentialSolution:  To resolve this problem, apply Update for Velocity 3.1 (KB600).Applies To:  VEL-584, VEL-692

PRB:  An unexpected application error may occur when you open Enrollment Manager if the Scanner, PIV or RUU is enabled

Symptom:  An unexpected application error occurred when opening the Enrollment Manger if the Scanner, PIV or RUU is enabled under Device Configuration, similar to the error listed below:

Function Name: ScannerSupport.InitRegionCombos
FunctionSubItem: 4
Number: -2147024770
Description: Automation error
The specified module could not be found

Cause:  This behavior is caused by a defective .dll file. Solution: To resolve this issue, apply ScanWex.dll version 9.3.13.4. This file is available in Update for Velocity 3.1 (KB600).

Applies To:  VEL-715

PRB:  An unexpected application error may occur when opening Guest or Unassigned Credential in the Enrollment Manager

Symptom:  An unexpected application error occurred when opening the Guest or Unassigned Credential in the Enrollment Manager, as shown below:

Function Name: frmCredential.LoadBiometricData
FunctionSubItem: 51
Number: 94
Description: Invalid use of Null

Solution: To resolve this problem, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-807

PRB:  Inputs report incorrect names

Symptom:  When an alarm is generated, the alarm will display with a different name in the Event Viewer and Alarm Viewer as well in Graphics Maps. In addition, the Report will show the incorrect input name.

Cause:  The specific cause of this defect is unknown at this time.  This problem was ONLY reproducible with the customer’s database.

Solution:  To resolve this issue, apply SDServer.exe version 3.1.600.4. This file is available in Update for Velocity 3.1 (KB600).

Applies To:  VEL-814

PRB:  An exception error occurred in the Enrollment Manager when adding a Credential Template on a UK Region setting

Symptom:  An exception error occurred in the Enrollment Manager when adding a Credential Template on a UK Region setting.

Solution: To resolve this problem, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-815

PRB:  Function Groups are being deleted from a Credential

Symptom:  When multiple Function Groups are assigned to a Credential, and a Velocity Operator deletes any one of them, they are all deleted from the Credential.

Solution: To resolve this issue, apply HirschFunctionGroup.dll version 3.1.600.1. This file is available in Update for Velocity 3.1 (KB600).

Applies To:  VEL-847

PRB:  An application error occurred when restarting the Velocity Services following a Database Application Role Password change

Symptom:  An application error may occur when restarting the Velocity Services after changing the Database Application Role Password.

Solution: To resolve this problem, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-850

PRB:  Unable to use the Service Control Manage (SCM) to stop the Velocity Extension Service

Symptom:  Unable to use the Service Control Manage (SCM) to stop the Velocity Extension Service when the DVR Reader Server Extension is Enabled.

Solution: To resolve this issue, apply HirschSensormaticExt version 3.1.600.1. This file is available in Update for Velocity 3.1 (KB600).

Applies To:  VEL-857

PRB:  SDServer Log Files do not display the full version number

Symptom:  Since the automating the build process with the new longer version numbers, the log files no longer display the accurate version string.

For Example:

DServer v
ersion 3.1.544.54 is only displaying 3.1.54 instead of 3.1.544.54 in the logs.
Solution:   To resolve this issue, apply SDServer.exe version 3.1.600.4 and DTServer.exe version 3.1600.4. These files are available in Update for Velocity 3.1 (KB600).Applies To:  VEL-874

PRB:  An unexpected error occurred when attempting to print from a Zebra ZXP-8 Badge Printer

Symptom:  An unexpected error occurred when attempting to print from a Zebra ZXP-8 Badge Printer, as shown below:

Description: Invalid property value
Function: PrintEngine.FPPreview.PrintPicture(23)
Error Number: 380

Solution: To resolve this problem, apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-877

Enhancements in Update for Velocity 3.1 (KB600)

ENH:  The “Show Last Door Name” for Credentials option will show the Door Name in the Enrollment Manager

Description:  Modified Enrollment Manager to add “Show Last Door Name” for Credential options to show the Door Name instead of the Door Address under the Last Door column.

To Enable or Disable the “Show Last Door Name” option:

1. Select View from the Enrollment Manager Main Menu.
2. Select to place a check mark on “Show Last Access for Credentials” and “Show Last Door Name”.

NOTE:  NO check mark will show the Door Address

To verify this function, select a User with Credential and view the Last Door column

Installation:  Apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-442

ENH:  Support for American Dynamics Intellex version 4.3

Description:  Support for American Dynamics Intellex version 4.3 has been added.

Installation:  Apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-537

ENH:  Card Scanning Solutions (CSSN) SDK Update 9.42.0

Description:  The SDK version has been updated to support the new Nevada Driver's License format.

Installation:  Apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-576

ENH:  Improve Velocity system performance when running large Archive Reports

Description:  Currently when a large archive file is being restored to the database for the purpose of generating a report, it runs at the same priority as everything else. Priority should be given to alarm reporting and event handling. Reports should run in the background.

This enhancement only affects the restoration of an archive table to the current database. It prevents that restoration from tying up the SQL server during the restoration period. The restoration will take place in the background allowing other processes to use the SQL server and preventing the archive process from starving the system of resources.

Installation:  Apply Update for Velocity 3.1 (KB600).

Applies To:  VEL-854

Known Issues

 

PRB:  Pelco DVR integration does not work in Windows Vista or Windows 7

Symptom:  Pelco DVR integration with Velocity does not work in Windows Vista or Windows 7

Cause:  Pelco do not support Vista or Windows 7 at this time.

Solution:  None at this time.

Workaround:  None at this time.

Status:  This is a known issue that will be addressed in a future release.

 

Applies To:  VEL-878

PRB: MATCH number generated by Batch Enroll Credentials does not match what is being displayed by Readers

Symptom:  The MATCH number on cards being enrolled using the Batch Enroll Credentials Function are different than what is being reported by readers.  As a result, the card won't perform the assigned function.

Cause:  Unknown at this time.

Solution:  None at this time.

Workaround:  Use the standard Enrollment process instead of the Batch Enrollment process.

Status:  This is a known issue that will be addressed in a future release.

 

Applies To:  VEL-896

 